=== NLQ1 ===
Buttons
Online Pause/Continue (LF can be used only when Paused) LF Line Feed (scroll to next line) PowerOn+LF Self-test (print test page until power-off or paper-out) PowerOn+LF+Online Enter Hex-dump debug mode (print all codes in hex)
LEDs
PowerLED (red)
PowerOn+LF+Online Select NLQ mode
PowerOn+LF Self-test (print test page until power-off or paper-out)
PowerOn+FF+LF +FF Enter Hex-dump debug mode (print all codes in hex) (DMP2xxx/3xxx) PowerOn+FF Unknown (another test/debug mode or so)
LEDs
Online
|DS2-1||Page length||11 inch (default)||12 inch||Can be also changed via ESC "C"
|-
|DS2-2||Line Feed Spacing||colspan=2|Force ESC "2" to act as 1/8 or 1/6 inch<br>Note: Service manual claims DS2-2 selects UK/French characters, that is wrong, not supported by firmware||ESC "2" cannot Can be reassigned by software (but software can use ESC "0", ESC "1", also changed via ESC "3A" to control linefeeds)
|-
|DS2-3||International characters||colspan=2|Select US-ASCII or German characters||Can be changed by ESC "6" / ESC "7" (which are NLQ401-specific codes, non-Epson compatible)
|-
|DS2-4||Draft/NLQ Mode||colspan=2|Select Draft or NLQ mode<br>Note: Service manual claims it slects selects Slashed/Unslashed Zero, that is wrong.||Can be also changed by ESC "x" (Epson-compatible code), or by ESC "I" (equivalent NLQ401-specific, non-Epson compatible code)
|-
|DS2-5||1 inch skip perforation||Invalid/Disable (default)||Valid/Enable||Can be also changed via ESC "N"/ESC "O"